HDMI 2.0 Design Does Not Work for Data Rates Below 600 Mbps - HDMI 2.0 Design Does Not Work for Data Rates Below 600 Mbps
Description When you run the Stratix V design for HDMI version 2.0 ( <IP root directory>/altera/altera_hdmi/hw_demo/sv_hdmi2 ), the design will not work for resolutions running at data rates below 600 megabits per second (Mbps). This issue is caused by a bug in the mr_rx_oversample block in the design that stops the HDMI RX core from locking resolutions that require oversampling. This issue only affects the HDMI 2.0 design for Stratix V devices. Resolution There is no workaround for this issue. This issue is fixed in version 15.0 Update 2 of the HDMI IP core.
Custom Fields values:
['novalue']
Troubleshooting
novalue
True
['novalue']
['FPGA Dev Tools Quartus II Software']
novalue
15.0
['Stratix® V FPGAs']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document