Why does the Quartus® Prime Pro Edition Software crash at the Timing Analysis stage without any message? - Why does the Quartus® Prime Pro Edition Software crash at the Timing Analysis stage without any message?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 22.4 and earlier, you may see the Quartus® Prime Pro Edition Software GUI crashes without any message at the Timing Analysis stage. The problem occurs when the Design Assistant rules RDC-50001 and RDC-50002 are enabled. Resolution To work around this problem, follow the steps below: Click Assignments > Settings Choose Design Assistant Rule Settings , uncheck RDC-50001 and RDC-50002 Re-run the Timing Analysis stage. This problem has been fixed from the Quartus® Prime Pro Edition Software Version 23.1.