The NoC Initiator IP does not execute reset correctly when configured in Fabric NoC mode, and the read transactions are in-flight. - The NoC Initiator IP does not execute reset correctly when configured in Fabric NoC mode, and the read transactions are in-flight.
Description In the Quartus® Prime Pro Software version 23.2, if the user asserts the AXI4 reset for the NoC Initiator IP configured in fabric NoC mode while the read responses are in-flight, the reset takes multiple cycles to execute. Therefore, the user may incorrectly receive the read responses requested before the reset was asserted. This issue impacts both simulation and hardware. Resolution Wait for all read responses to complete before asserting the reset. This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.