Why do I see a mismatch in the ALM utilization figures reported in the Resource Usage Summary and Fitter Resource Utilization by Entity sections of the fitter report? - Why do I see a mismatch in the ALM utilization figures reported in the Resource Usage Summary and Fitter Resource Utilization by Entity sections of the fitter report?
Description Due to a problem in the Quartus® II software versions 11.0 SP1 and earlier, the Adaptive Logic Module (ALM) utilization reported in the F itter Resource Utilization by Entity section of the fitter report may be incorrect for Stratix® V and Arria® V designs. Resolution The number of ALMs reported in the Resource Usage Summary section of the fitter report is correct.
Custom Fields values:
['novalue']
Troubleshooting
n/a
False
['novalue']
['FPGA Dev Tools Quartus II Software']
No plan to fix
11.0
['Arria® V GT FPGA', 'Arria® V GX FPGA', 'Arria® V ST FPGA', 'Arria® V SX FPGA', 'Stratix® V E FPGA', 'Stratix® V FPGAs', 'Stratix® V GS FPGA', 'Stratix® V GT FPGA', 'Stratix® V GX FPGA']
['novalue']
['novalue']
['novalue'] - 2023-03-28
external_document