Error(20561): IOPLL <name> could not be placed in location <location> because this location cannot be used by IOPLLs using Normal or Source Synchronous Compensation - Error(20561): IOPLL <name> could not be placed in location <location> because this location cannot be used by IOPLLs using Normal or Source Synchronous Compensation
Description You may see this error in the Quartus® Prime Pro Edition Software v21.3 and earlier when using IOPLLs in Banks 3C and 3D in Agilex™ 7 F-Series SoC FPGA devices. The error occurs because the HPS Shared GPIO Banks (3C & 3D) do not support IOPLLs in Normal and Source Synchronous compensation modes. Resolution If the IOPLL needs to operate in Normal or Source Synchronous modes, select a location that is not adjacent to the HPS Bank. Alternatively, choose another IOPLL compensation mode.
Custom Fields values:
['novalue']
Troubleshooting
18017360102, 14015052200
False
['IOPLL IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
21.3
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2024-11-05
external_document