Why does the GTS JESD204B/C FPGA IP and Design Example generation fail on Agilex™ 3 FPGA and Agilex™ 5 FPGA devices when selecting System or HVIO PLL clocking mode? - Why does the GTS JESD204B/C FPGA IP and Design Example generation fail on Agilex™ 3 FPGA and Agilex™ 5 FPGA devices when selecting System or HVIO PLL clocking mode? Description Due to a problem in the Quartus® Prime Pro Edition software version 25.3, you may encounter an error message like the following when generating the GTS JESD204B/C FPGA IP Design Example. "Error: phy_inst.inst_directphy: System/HVIO PLL frequency "307.2" cannot be smaller than transceiver's parallel clock frequency "858.0" The following IP configuration steps may lead to the above error: Set the Data rate to a specific value Set the Datapath clocking mode System PLL Enable the example design generation Enable Simulation and/or Synthesis in the Example Design Files section Increase the data rate to a value higher than the data rate set in step 1 Generate the IP or Example Design *Note that this problem will not occur when you use a data rate set in Step 5 lower than the data rate set in Step 1. Resolution When you encounter this error, use the following workaround: Disable example design generation Update the System PLL frequency for the latest data rate Enable example design generation Generate the IP or Example Design This problem will be fixed in a future release of the Quartus Prime Pro Edition Software. Custom Fields values: Troubleshooting 15018458319 ['Interfaces JESD204C (Primary)', 'Interfaces JESD204B (Primary)'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 25.3 ['Agilex™ 5 FPGAs and SoCs', 'Agilex™ 3 FPGAs and SoCs'] - 2025-10-14