Why won't my Arria V GX bonded transceiver instance fit in Banks GXB_R0 and GXB_R1? - Why won't my Arria V GX bonded transceiver instance fit in Banks GXB_R0 and GXB_R1?
Description In Arria ® V GX 18-transceiver devices, the upper three transceiver channels of bank GXB_R0 are unavailable for bonding. Any transceiver instances that must bond across banks GXB_R0 and GXB_R1 will not fit. These unavailable three channels are highlighted in Figure 1-2, Volume 2 of the Arria V Handbook. http://www.altera.com/literature/hb/arria-v/av_5v3.pdf Resolution For transceiver instances that must bond across two transceiver banks in an 18-channel Arria V GX device, the transceivers must be placed in bank GXB_L0 and GXB_L1.