Why does programming of EPCQ-L configuration devices fail when using Intel® Quartus® Prime Programmer Pro Edition Software version 21.1 and later? - Why does programming of EPCQ-L configuration devices fail when using Intel® Quartus® Prime Programmer Pro Edition Software version 21.1 and later?
Description Due to EPCQ-L configuration devices having been discontinued (refer to PDN1802 ), EPCQ-L configuration device programming with a JIC file will fail when using Intel® Quartus® Prime Programmer Pro Edition Software version 21.1 and later. You may see the following error messages when the problem occurs: Error(19118): Erase failed on flash 1 at address 0x00000000 Error(18939): Unexpected error in JTAG server: Timeout Error(209012): Operation failed Resolution To work around this, use Intel® Quartus® Prime Programmer Pro Edition Software version 20.4 or earlier to program the EPCQ-L flash device .