Why are the HSSI_PARAMETER settings included in the Ignored Assignments list of the Fitter report for my Intel Agilex® 7 FPGA F-tile design in the Intel® Quartus® Prime Software version 22.2 and earlier? - Why are the HSSI_PARAMETER settings included in the Ignored Assignments list of the Fitter report for my Intel Agilex® 7 FPGA F-tile design in the Intel® Quartus® Prime Software version 22.2 and earlier? Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.2 and earlier, the HSSI_PARAMETER instance assignments might be found in the Ignored Assignments list of the Fitter report after compiling an Intel Agilex® 7 FPGA F-tile design. You can safely disregard these Ignored Assignments, as they are applied at the Support Logic Generation stage. You may check if the HSSI_PARAMETER settings have been applied through the Assignment Editor in the Intel® Quartus® Prime Pro Edition Software. Resolution This problem will be fixed in a future release of the Intel® Quartus® Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting 15011156071 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 23.2 22.2 ['Agilex™ 7 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-05-19