Why does the In-System Memory Content Editor display incorrect Instance ID? - Why does the In-System Memory Content Editor display incorrect Instance ID? Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 23.1 and earlier, you might see the Instance ID is displayed incorrectly as default "NONE" in the In-System Memory Content Editor (ISMCE). Resolution To work around this problem, follow these steps: 1. Go to <Quartus_installed_directory>\ip\altera\sld\jtag\intel_mce\intel_mce_hw.tcl 2. At line 111, change NODE_NAME type from NATURAL to STRING as the following: add_parameter NODE_NAME STRING 0 3. Regenerate HDL of related IP, recompile and reprogram the .sof file This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 23.2. Custom Fields values: ['novalue'] Troubleshooting 15012605919 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 23.2 23.1 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2023-11-16