Why does the Siemens* ModelSim* simulation stop unexpectedly when using the SDI II IP Multi-Rate Parallel loopback without an external VCXO design? - Why does the Siemens* ModelSim* simulation stop unexpectedly when using the SDI II IP Multi-Rate Parallel loopback without an external VCXO design?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 23.4, the ModelSim* testbench fails when simulating the SDI II Multi-rate Parallel loopback without external VCXO design. Resolution To work around this problem, please update the testbench by connecting the gxb_tx_reconfig_xcvr_clk to the tb_test_control_rx_coreclk . This problem is fixed starting with Quartus® Prime Pro Edition Software version 24.1.
Custom Fields values:
['novalue']
Troubleshooting
15014746534
False
['SDI II IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
24.1
23.4
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2025-05-06
external_document
- Resource Type
- Support Resources > Knowledge Articles
- Source Name
- khoros