Why does the P-Tile Avalon® Streaming Intel® FPGA IP for PCI Express VirtIO configuration register access return unexpected result when multiple physical function or SR-IOV is enabled ? - Why does the P-Tile Avalon® Streaming Intel® FPGA IP for PCI Express VirtIO configuration register access return unexpected result when multiple physical function or SR-IOV is enabled ?
Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.3 and 21.4, you might see that the Configuration Write or Read to P-Tile Avalon® Streaming Intel® FPGA IP for PCI Express VirtIO configuration space register return unexpected result when the following Hard IP Mode is selected: Gen4x16, Interface - 512-bit (PLD Clock Frequency: 175/200/225/250 MHz) Gen4x8, Interface - 512-bit (PLD Clock Frequency: 175/200/225/250 MHz) Gen4x8, Interface - 256-bit (PLD Clock Frequency : 175/200/225/250 MHz) Resolution This problem is fixed beginning with the Intel® Quartus® Prime Pro Edition Software version 22.1.
Custom Fields values:
['novalue']
Troubleshooting
15010331486, 15010366808
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
22.1
21.2
['Agilex™ 7 FPGA F-Series', 'Stratix® 10 DX FPGA']
['novalue']
['novalue']
['novalue'] - 2023-01-10
external_document