How do I enable debug endpoint for transceiver toolkit (ADME) for the F-Tile 25G Ethernet Soft-IP to use the Transceiver Toolkit? - How do I enable debug endpoint for transceiver toolkit (ADME) for the F-Tile 25G Ethernet Soft-IP to use the Transceiver Toolkit?
Description The F-Tile 25G Ethernet IP (alt_e25_f) does not expose the "Enable debug endpoint for transceiver toolkit" option in the IP Parameter Editor GUI. As a result, users cannot enable Transceiver Toolkit access through the standard IP configuration interface. Resolution To enable debug endpoint for transceiver toolkit for the F-Tile 25G Ethernet IP, use the following workaround: To enable the debug endpoint for the Transceiver Toolkit, use the following workaround: Open the .ip file for the F-Tile 25G Ethernet Soft IP . Locate the ENABLE_ADME_GUI parameter. Change its value from 0 to 1 . Save the .ip file. Regenerate the IP. Note: This workaround modifies a hidden parameter that is not officially available in the GUI. The parameter implementation may change in future releases. After upgrading Quartus® Prime software, verify that the functionality continues to operate as expected.
Custom Fields values:
Errata
QS-605554
novalue
['Interfaces Ethernet']
['FPGA Dev Tools Quartus® Prime Software Pro']
No plan to fix
25.1
['Agilex® 7 FPGAs and SoCs'] - 2026-07-13
external_document
- Resource Type
- Support Resources > Knowledge Articles
- Source Name
- khoros