MAX®10 FPGA OPN 10M16SLY180C8G is not in the PDN device selection list. How should I calculate the decoupling capacitor requirements for this device? - MAX®10 FPGA OPN 10M16SLY180C8G is not in the PDN device selection list. How should I calculate the decoupling capacitor requirements for this device?
Description MAX®10 FPGA OPN 10M16SLY180C8G is not in the PDN (Power Distribution Network) version 2.0 selection list. Resolution To evaluate decoupling requirements for a MAX® 10 FPGA device, you can use the device-agnostic version of the Altera® Power Delivery Network (PDN) Tool. Since the MAX10-SL-specific PDN is not available, we have several development kits that use this approach. To calculate the target impedance of each MAX® 10 FPGA device supply, you should use the following transient current and voltage ripple percentages: MAX®10 FPGA Supply Rail Transient Current Voltage Ripple VCC 50% 5% VCCIO 100% 5% VCCA 10% 5% VCCD_PLL 10% 3% VCCA_ADC 50% 2% VCCINT 50% 3% Setting Ftarget to 70MHz or higher should result in a robust PDN for this part number.