Error (15065): Clock input port inclk[0] of PLL "lvds_tx_pll" must be driven by a non-inverted input pin or another PLL, optionally through a Clock Control block - Error (15065): Clock input port inclk[0] of PLL "lvds_tx_pll" must be driven by a non-inverted input pin or another PLL, optionally through a Clock Control block
Description You may see this error when implementing the MAX® 10 Soft TX LVDS IP in External PLL mode, using Quartus® II software version 14.1 and later. The tx_inclock is missing from the RTL source file. Resolution To work around this problem, change the Altera Soft LVDS TX IP to internal PLL mode or enable the "Register \'tx_in\' input port" option on the Transmitter Settings tab of the MAX® 10 Soft TX LVDS MegaWizard™ Plug-In Manager. This problem is scheduled to be fixed in a future version of the Quartus® II software.
Custom Fields values:
['novalue']
Troubleshooting
1506817950
False
['novalue']
['FPGA Dev Tools Quartus II Software']
15.1
14.1
['MAX® 10 10 FPGAs']
['novalue']
['novalue']
['novalue'] - 2023-03-13
external_document