Error (175005): Could not find a location with: PMA_DIRECT_CHANNEL - Error (175005): Could not find a location with: PMA_DIRECT_CHANNEL
Description You may see the above Quartus® II software fitter error when placing a transceiver channel with standard PCS enabled in channels Ch1 and Ch2 of GXB_L0 and GXB_R0 on Arria® V GX, SX, GT, and ST devices. The error occurs when the "Enable rx_pma_clkout port" option is enabled in the Arria V Native PHY IP. Due to Arria® V GX, SX, GT, and ST device limitations, the parallel recovered clock from the CDR and deserializer can not be routed to the FPGA fabric. Resolution To work around this problem, you must deselect the "Enable rx_pma_clkout port" option in the Native PHY IP.
Custom Fields values:
['novalue']
Troubleshooting
9237992791
False
['Arria® V Transceiver Native PHY IP']
['FPGA Dev Tools Quartus II Software']
novalue
No plan to fix
['Arria® V FPGAs and SoCs', 'Arria® V GT FPGA', 'Arria® V GX FPGA', 'Arria® V ST FPGA', 'Arria® V SX FPGA']
['novalue']
['novalue']
['Arria® V GT FPGA Dev Kit'] - 2023-03-27
external_document