Can I manually set the voltage of a pre-driver voltage supply (VCCPD) of a particular bank, in the Quartus II design software? - Can I manually set the voltage of a pre-driver voltage supply (VCCPD) of a particular bank, in the Quartus II design software? Description No, you cannot manually set the VCCPD voltage supply of a particular bank in the Quartus® II design software, since the required VCCPD voltage of a bank is dependent upon it's respective VCCIO. The required VCCPD voltage is derived by the Quartus II design software from the respective VCCIO setting. To make a voltage assignment to the VCCIO supply of a bank, you can use the following assignment: set_global_assignment -name IOBANK_VCCIO <voltage> -section_id <bank> Where <voltage> is the required voltage (e.g. 3.3V) and <bank> is the bank number (e.g. 3C). Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['novalue'] novalue novalue ['Arria® V FPGAs and SoCs', 'Cyclone® V FPGAs and SoCs', 'Stratix® III FPGAs', 'Stratix® IV FPGAs', 'Stratix® V FPGAs'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25