Why does the Power Analyzer not report total current for VCCA_FPLL in Cyclone® V devices? - Why does the Power Analyzer not report total current for VCCA_FPLL in Cyclone® V devices?
Description The Power Analyzer report in the Quartus® II software up to version 12.1 SP1 does not show a voltage supply for VCCA_FPLL in Cyclone® V devices. This is a mistake with the voltage supply labels in the Current Drawn from Voltage Supplies Summary. The current drawn from VCCA_FPLL is shown as VCCEH_GXB in this report. VCCEH_GXB is not a valid Cyclone V device family power supply name. Resolution Use the current values reported for VCCEH_GXB for your power estimation of VCCA_FPLL . This problem is fixed in the Quartus® II software version 13.0
Custom Fields values:
['novalue']
Troubleshooting
1408016534
False
['novalue']
['FPGA Dev Tools Quartus II Software']
13.0
12.1
['Cyclone® V E FPGA', 'Cyclone® V GT FPGA', 'Cyclone® V GX FPGA', 'Cyclone® V SE FPGA', 'Cyclone® V ST FPGA', 'Cyclone® V SX FPGA']
['novalue']
['novalue']
['novalue'] - 2023-03-13
external_document