Can not program Agilex-5 device - Can not program Agilex-5 device
Quartus programmer stops at 44% with error: Error(18950): Device has stopped receiving configuration data Error(18948): Error message received from device: Bitstream error. (Subcode 0x0093, Info 0x00000003, Location 0x00000800) Error(18948): Error message received from device: Device specification (SKU ID) of the target device used in bitstream generation does not match physical device. Error(23925): Debug suggestion: Verify that the device OPN selected in Quartus Prime matches exactly with the OPN of your hardware device. Error(209012): Operation failed What can be the cause, the device is selected correctly.
Replies:
Re: Can not program Agilex-5 device
I’m glad that your question has been addressed, I now transition this thread to community support. This thread will be transitioned to community support. If you have a new question, feel free to open a new thread to get support from Altera experts. Otherwise, the community users will continue to help you on this thread. Thank you.
Replies:
Re: Can not program Agilex-5 device
Problem solved I had to use special "CS" OPN. Then it all worked.
Replies:
Re: Can not program Agilex-5 device
Hi AnttiLukats, The errors you see match a known case where the timing models for this device are not yet final. Hence SOF generation also is not enabled yet.. Please review: KDB : Why can’t the Agilex 5/7 programming file be generated? https://community.altera.com/kb/knowledge-base/why-cant-the-agilex%E2%84%A2-5-or-agilex%E2%84%A2-7-fpga-programming-file-be-generated-in-the-qu/345059 Community thread showing the workaround via quartus.ini and correct OPN selection : https://community.altera.com/discussions/quartus-prime/quartus-25-1-0-not-producing-sof-file/311247 Next steps: In Quartus, select the exact Ordering Part Number printed on your device and recompile. Update to the latest Quartus Prime Pro with the Agilex 5 device pack. If Warning 18636 still blocks .sof, I will request the temporary INI from software team, then recompile and program. Regards, Fakhrul
Replies:
Re: Can not program Agilex-5 device
we tried flashing with wrong SOF, when we select proper device then SOF is not generated at all, with following: Critical Warning(18636): Compilation Report contains advance information. Specifications for device A5EE013BB23BE6S are subject to change. Contact Altera for information on availability. No programming file will be generated. Dear Altera what should we do? - 2026-02-12