Internal Error: Sub-system: PTI, File: /quartus/tsm/pti/pti_tdb_builder.cpp, Line: 5410 - Internal Error: Sub-system: PTI, File: /quartus/tsm/pti/pti_tdb_builder.cpp, Line: 5410
Description Due to a problem in the Quartus® Prime Pro Edition Software version 24.2 and earlier, you might see this error when the cascade_out port of an IOPLL FPGA IP is connected to logic other than the refclk port of another IOPLL. Internal Error: Sub-system: PTI, File: /quartus/tsm/pti/pti_tdb_builder.cpp, Line: 5410 ATOM *|iopll_0|tennm_pll Type: FALCONMESA_IOPLL (atom id 309) with OTERM type O_PLL_CASCADE_OUT[0] does not lead to top-level port when it wants to reach ITERM type CLK[0] of ATOM Resolution To work around this problem, do not connect the cascade_out port of an IOPLL IP is connected to logic other than the refclk port of another IOPLL.
Custom Fields values:
['novalue']
Troubleshooting
18039470653
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
23.4
['Arria® 10 FPGAs and SoCs', 'Cyclone® 10 GX FPGA', 'Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2025-06-10
external_document