SDC_ENTITY_FILE critical warnings - SDC_ENTITY_FILE critical warnings When building a platform designer based system using quartus pro 25.1 I see a number of the following warnings when running the fitter. Critical Warning(22304): SDC_ENTITY_FILE '../../phoenix/DesignFiles/platform_designer/ip/print_sys/pcc3e/pcc2e_print_memory/altera_reset_controller_1924/synth/altera_reset_controller.sdc' was not applied. No matching entity: 'altera_reset_controller' in library: 'altera_reset_controller_1924'. The altera_reset_controller is listed in the altera_reset_controller_1924 library under the quartus design units tab. Given this, why do these warnings occur? Kind regards, Graeme Replies: Re: SDC_ENTITY_FILE critical warnings May I know does the problem resolved after changing the file order? Replies: Re: SDC_ENTITY_FILE critical warnings I found that by changing the analysis order so that the first altera reset controller analyzed was from the qsys directory, not an ip directory, this problem did not occur Regards Graeme Replies: Re: SDC_ENTITY_FILE critical warnings Please let me know if the provided solution resolves your issue. Regards, Richard Tan Replies: Re: SDC_ENTITY_FILE critical warnings Please proceed with sstrell’s suggestion by re-adding the component and regenerating the HDL. Should the issue persist, kindly share the .QAR file (Project → Archive Project) so that I can reproduce the warning behavior from my side. Regards, Richard Tan Replies: Re: SDC_ENTITY_FILE critical warnings Does the system generate successfully if you manually generate it in PD? Have you tried deleting and re-adding that component in the system? - 2026-01-22