Why don’t I see critical warnings for ATX or fPLL spacing violations for the Arria® 10 FPGA device project when using the Quartus® Prime Pro Software versions 19.1 to 22.2? - Why don’t I see critical warnings for ATX or fPLL spacing violations for the Arria® 10 FPGA device project when using the Quartus® Prime Pro Software versions 19.1 to 22.2?
Description Due to a bug in the Quartus® Prime Pro software versions 19.1 to 22.2, you will not see a critical warning for ATX PLL or fPLL spacing if you violate the requirements documented in section 3.1.1. Transmit PLLs Spacing Guideline when using ATX PLLs and fPLLs of the Arria® 10 Transceiver PHY User Guide. It is mandatory to meet the ATX PLL-to-ATX PLL Spacing Guidelines and ATX PLL-to-fPLL Spacing Guidelines documented in the Arria® 10 Transceiver PHY User Guide. Resolution This critical warning omission messaging was fixed in Quartus® Prime Pro software version 22.3.
Custom Fields values:
['novalue']
Troubleshooting
18021750227
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
22.3
19.1
['Arria® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2025-05-15
external_document