How do I configure the Intel® Quartus® Prime Pro software to use an Intel Enpirion® EM22x device as a SmartVID Power Management Controller for Intel Stratix® 10 devices? - How do I configure the Intel® Quartus® Prime Pro software to use an Intel Enpirion® EM22x device as a SmartVID Power Management Controller for Intel Stratix® 10 devices?
Description Intel® Enpirion® EM2260 / EM22xx parts can be used as Power Management Controllers for SmartVID enabled variants of Intel Stratix® 10 devices. Follow the instructions below to configure the Intel Quartus® Prime Pro software for this use case. Resolution In the Device and Pin Options dialog box in Intel Quartus Prime Pro Software, under Power management and VID tab select : Bus Speed mode : 100 KHz / 400 KHz Slave Device type : Other PMbus Device X Slave address : Set the PMbus address in hex without the '0x' prefix Voltage Output format : Linear Intel Enpirion devices only support Linear mode If Auto Discovery is selected, set the direct coefficients m/b/r to 0 Linear format N : -13 Translated voltage value unit : Volts Enable PAGE command : Leave this disabled (Default) Intel Enpirion devices do not support PAGE command