Why does the simulation for Arria®10 EMIF IP in Mentor simulators hang when using the Quartus® Prime Standard Edition Software version 22.1? - Why does the simulation for Arria®10 EMIF IP in Mentor simulators hang when using the Quartus® Prime Standard Edition Software version 22.1? Description Arria® 10 EMIF IP Simulation hangs in the Mentor simulator when calibration mode in EMIF IP GUI is set to “ Skip ”. To work around the problem in the Quartus® Prime Standard Edition Software version 22.1, set calibration mode in Arria 10 EMIF IP GUI to Abstract PHY calibration mode . Resolution This problem is scheduled to be fixed in the Quartus® Prime Standard Edition version 24.1 Software. Custom Fields values: ['novalue'] Troubleshooting 14017899449 True ['External Memory Interfaces Arria® 10 FPGA IP'] ['FPGA Dev Tools Quartus® Prime Software Standard'] 24.1 22.1 ['Arria® 10 Bare Die'] ['Simulation Development Tools'] ['novalue'] ['novalue'] - 2023-08-28