Why does the F-Tile Ethernet Dynamic Reconfiguration (DR) design not work when one of the profiles has PTP enabled? - Why does the F-Tile Ethernet Dynamic Reconfiguration (DR) design not work when one of the profiles has PTP enabled? Description Due to a problem in the Quartus® Prime Pro Edition software version 23.3, the F-Tile Ethernet designs using Dynamic Reconfiguration with PTP enabled on some of the profiles will fail to work correctly if the startup profile of the design does not have PTP enabled. Resolution To work around this problem, ensure that the startup profile of your dynamically reconfigurable Ethernet design has PTP enabled if any of the profiles have PTP enabled. This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition software. Custom Fields values: ['novalue'] Troubleshooting 15014436247 False ['F-Tile Dynamic Reconfiguration Suite IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 24.2 ['Agilex™ 5 FPGAs and SoCs', 'Agilex™ 7 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2025-06-16

external_document