Does the FFT MegaCore implement the Global Clock Enable feature for the Floating Point Variable Streaming? - Does the FFT MegaCore implement the Global Clock Enable feature for the Floating Point Variable Streaming?
Description The FFT MegaCore® does not implement the Global Clock Enable feature for the Floating Point variable streaming. T he following error messages will appear when both “Global Clock Enable” and “Floating Point” are selected: MegaCore Function Generation Error IP Functional Simulation Model Creation Failed. The following error was returned: Error: Quartus II 32-bit Analysis & Synthesis was unsuccessful, 1 error, 1 warning This error message is given when generating the FFT MegaCore Functional Simulation Model Error (12002): Port "clk_ena" does not exist in macrofunction "apn_fftfp_top_fft_130_inst" This error message is given when the Quartus® II software performs Analysis & Synthesis Resolution This issue will be fixed in a future version of the Quartus II software.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['novalue']
novalue
novalue
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document