Why does the serdes_pll_locked signal of upper PCI* Express Hard IP of Intel® Cyclone® V devices does not lock? - Why does the serdes_pll_locked signal of upper PCI* Express Hard IP of Intel® Cyclone® V devices does not lock?
Description Due to a problem with Intel® Quartus® prime Software, Intel® Cyclone® V device that include 6 transceiver channels and two PCIe* Hard IPs will see a problem where the upper PCIe* Hard IP's serdes_pll_locked signal is unable to lock. The lower PCIe Hard IP does not has this issue and is working correctly. Resolution To work around this problem, run the enable_rx_pma_direct.xml script on top of the Quartus-generated SOF file. Run the script from the command line as shown below, download the .xml script from here and run it from the same directory as the Quartus project file (.qpf). quartus_asm -e <name_of_sof> -x enable_rx_pma_direct.xml
Custom Fields values:
['novalue']
Troubleshooting
FB: 530556;
False
['Cyclone® V Hard IP for PCI Express IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
No plan to fix
16.1
['Cyclone® V FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2022-12-22
external_document