Why does the design example simulation not complete for E-Tile Hard IP for Ethernet Intel® Stratix® 10 FPGA IP variant when selecting “AN/LT” and “PCS_only” options? - Why does the design example simulation not complete for E-Tile Hard IP for Ethernet Intel® Stratix® 10 FPGA IP variant when selecting “AN/LT” and “PCS_only” options? Description Due to a problem in the Intel® Quartus® Prime software version 19.1 and earlier, the design example testbench for E-Tile Hard IP for Ethernet Intel® Stratix® 10 FPGA IP variant with “ AN/LT ” and “ PCS_only ” options selected will not complete. Resolution To work around this problem, perform the following steps: 1.) Navigate to the alt_ehip3_0_example_design/example_testbench directory 2.) Open the “basic_avl_tb_top.sv” file 3.) Change line 461 FROM: #5000 i_reconfig_clk = ~i_reconfig_clk; TO: #500 i_reconfig_clk = ~i_reconfig_clk; 4.) Rerun simulation This problem is scheduled to be fixed in a future release of the Intel® Quartus® Prime software. Custom Fields values: ['novalue'] Troubleshooting 2207232092 False ['E-tile Hard IP for Ethernet IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 19.2 18.1.1 ['Stratix® 10 MX FPGA', 'Stratix® 10 TX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25