Error(332000): ERROR: You must run the read_atom_netlist command first to initialize the netlist - Error(332000): ERROR: You must run the read_atom_netlist command first to initialize the netlist Description In the Quartus® Prime Pro Edition Software v21.3 and earlier, you may see this error when compiling designs that include the LVDS SERDES FPGA IP in external phase-locked loop (PLL) mode. This error occurs when the LVDS SERDES FPGA IP is listed above the IOPLL FPGA IP in the Quartus® Settings File (QSF). Resolution To avoid this error, make sure the IOPLL FPGA IP is listed above the LVDS SERDES FPGA IP in the Quartus® Settings File (QSF). A more helpful error message is scheduled to be added to a future release of the Quartus® Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting 18018492314 False ['IOPLL IP', 'LVDS SERDES IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 23.3 19.1 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2024-11-15