Why are the CONF_DONE and INIT_DONE signals not de-asserted once nCONFIG goes low in Intel® Stratix® 10 and Intel Agilex® 7 FPGAs operating in PMBus Agent Mode? - Why are the CONF_DONE and INIT_DONE signals not de-asserted once nCONFIG goes low in Intel® Stratix® 10 and Intel Agilex® 7 FPGAs operating in PMBus Agent Mode? Description When using Intel® Stratix® 10 and Intel Agilex® 7 FPGAs, CONF_DONE and INIT_DONE signals typically go low in less than 1 ms after nCONFIG goes low. In PMBus (SmartVID) Agent mode, it may take a longer time for the Secure Device Manager (SDM) to de-assert the CONF_DONE and INIT_DONE , depending on when the VOUT_COMMAND is issued by the external host. In this mode, a handshake between the PMBus host and FPGA is required to adjust the core power supplies to the nominal value after nCONFIG goes low. The SDM de-asserts the CONF_DONE and INIT_DONE signal only after receiving the VOUT_COMMAND from the external host. Resolution This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 21.1. Custom Fields values: ['novalue'] Troubleshooting 18010932026 False ['User Reset and Clock Gate Stratix® 10 FPGA IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 21.1 19.4 ['Agilex™ 7 FPGAs and SoCs', 'Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-06-06