Can I power the HPS rails with a fixed voltage supply on SmartVID enabled Stratix® 10 FPGAs? - Can I power the HPS rails with a fixed voltage supply on SmartVID enabled Stratix® 10 FPGAs?
Description Yes, the HPS on SmartVID enabled variants of Stratix® 10 FPGAs can be powered up with a fixed voltage. The VCCL_HPS and VCCPLLDIG_HPS voltage rails can be connected to a fixed supply of 0.9V or 0.94V. The VCC and VCCP rails however must be connected to a voltage regulator that supports SmartVID capability. Resolution This information is scheduled to be added to a future release of the Stratix® 10 Device Datasheet .
Custom Fields values:
['novalue']
Troubleshooting
1807114711
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
No plan to fix
18.1
['Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2024-11-28
external_document