Simulation Runs Infinitely When Using The SDI II MegaCore Design Testbench - Simulation Runs Infinitely When Using The SDI II MegaCore Design Testbench Description When you simulate the generated SDI II MegaCore design example, the simulation runs infinitely. The simulation testbench fails if you set the following features of the SDI II MegaCore to create the design example: Select Triple Standard for the Video Standard option Turn on the Tx PLL Dynamic Switching option Turn on the Increse Error Tolerance Level option This issue affects the SDI II MegaCore in Quartus II software version 13.0SP1. Resolution None. This issue will be fixed in Quartus II software version 13.1. Custom Fields values: ['novalue'] Troubleshooting novalue True ['novalue'] ['FPGA Dev Tools Quartus II Software'] 13.1 13.0.1 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25