Error (12252): Link_test_sopc_sys.clk.clk_reset/checker_0.csr_clk_reset: Missing connection end (try "Remove Dangling Connections") - Error (12252): Link_test_sopc_sys.clk.clk_reset/checker_0.csr_clk_reset: Missing connection end (try "Remove Dangling Connections") Description You may encounter the following Quartus® II errors if you try to recompile the Stratix® IV and V Transceiver Toolkit version 12.1 design examples with Quartus II 13.0: Error (12252): Link_test_sopc_sys.clk.clk_reset/checker_0.csr_clk_reset: Missing connection end (try "Remove Dangling Connections") Error (12252): Checker_0_csr_slave_translator.avalon_anti_slave_0: Cannot connect checker_0_csr_slave_translator.reset because checker_0.reset is not connected Error (12077): Node instance "auto_hub" instantiated with unknown parameter "BROADCAST_FEATURE" Resolution Perform the following steps in Qsys to remove the errors: Click "Remove Dangling Connections". Provide resets to the generator and checker blocks. Remove the files with prefix "sld_*" from the Megafunctions™ folder in the design example. Custom Fields values: ['novalue'] Troubleshooting novalue False ['Reset'] ['novalue'] novalue novalue ['Stratix® IV FPGAs', 'Stratix® IV GT FPGA', 'Stratix® IV GX FPGA', 'Stratix® V GS FPGA', 'Stratix® V GT FPGA', 'Stratix® V GX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25