SerialLite III Streaming IP Core Regeneration Issue - SerialLite III Streaming IP Core Regeneration Issue
Description When the Quartus II MegaWizard Plug-In Manager generates the SerialLite III Streaming IP core, the clkctrl.v file is not created together with all other design files and is not included in <variation_name> .qip . This impacts the parameter setting of the device family. This issue affects the SerialLite III Streaming IP core in Quartus II software version 13.0. Resolution Perform the following steps to regenerate the SerialLite III Streaming IP core: Launch the Quartus II software. Open any project file that uses the Stratix V device (does not need to be a project that includes this core). Open the MegaWizard Plug-In Manager to read the existing SerialLite III Streaming IP core file. Click Finish to regenerate the core. This issue is fixed in version 13.1 of the SerialLite III Streaming IP core.