Why are the number of frame errors sent and detected not the same when using the Intel® Quartus® Prime Pro Edition Software Fault Injection Debugger tool? - Why are the number of frame errors sent and detected not the same when using the Intel® Quartus® Prime Pro Edition Software Fault Injection Debugger tool? Description Due to a known problem in the Intel® Quartus® Prime Pro Edition Software v19.3 and later, you may observe that the number of frame errors sent and detected when injecting faults into Intel® Stratix® 10 devices using the Fault Injection Debugger is not the same. Resolution This problem is partially fixed in Intel® Quartus® Prime Pro Edition Software v21.3. However a reporting discrepancy may still be seen if a fault is injected into a LUT RAM cell. The full fix is scheduled for a later version of the Intel Quartus Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting 1508723759, 1509201786 False ['Generic Component'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 21.3 19.3 ['Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2021-10-15