PSIRT Advisory – INTEL-SA-01104 - Intel® FPGA SDK for OpenCL™ Software Technology Advisory Intel® FPGA SDK for OpenCL™ Software Technology Advisory Corporate Pages Security {"description":"Intel\u00ae FPGA SDK for OpenCL\u2122 Software Technology Advisory. Altera\u2019s Product Security Incident Response Team (PSIRT) advisories provide important disclosures, mitigations, and security updates.","title":"PSIRT Advisory \u2013 INTEL-SA-01104"} Altera Security Advisory: INTEL-SA-01104 Advisory Category: Software Impact of vulnerability: Escalation of Privilege Severity rating: Medium Original release: 08/13/2024 Last revised: 05/06/2026 Summary: A potential security vulnerability in some Intel® FPGA SDK for OpenCL™ software technology may allow escalation of privilege. Intel is not releasing updates to mitigate this potential vulnerability and has issued a Product Discontinuation Notice for Intel® FPGA SDK for OpenCL™ software technology. Vulnerability Details: CVEID: CVE-2024-23909 Description: Uncontrolled search path in some Intel® FPGA SDK for OpenCL™ software technology may allow an authenticated user to potentially enable escalation of privilege via local access. CVSS Base Score 3.1: 6.7 Medium CVSS Vector 3.1: CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H CVSS Base Score 4.0: 5.4 Medium CVSS Vector 4.0: CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Affected products: Intel® FPGA SDK for OpenCL™ software technology, all versions. Recommendations: Intel has issued a product discontinuation notice for Intel® FPGA SDK for OpenCL™ software technology and recommends that users of the Intel® FPGA SDK for OpenCL™ software technology migrate to Intel® FPGA Add-on for oneAPI Base Toolkit at their earliest convenience. Intel® FPGA Add-on for oneAPI Base Toolkit: https://www.intel.com/content/www/us/en/developer/tools/oneapi/fpga.html Acknowledgements: Intel would like to thank ycdxsb for reporting this issue. Revision Date Description 1.0 08/13/2024 Initial Release 1.1 05/06/2026 Transfer Advisory to Altera. Legal Notices and Disclaimers Altera provides these materials as-is, with no express or implied warranties. All products, dates, and figures specified are preliminary based on current expectations, and are subject to change without notice. Altera products and services described may contain design defects or errors known as errata, which may cause the product to deviate from published specifications. Current characterized errata are available on request. Altera products that have met their End of Servicing Updates may no longer receive functional and security updates. Altera technologies’ features and benefits depend on system configuration and may require enabled hardware, software, or service activation. Performance varies depending on system configuration. No product or component can be absolutely secure. Check with your system manufacturer or retailer or learn more at https://www.altera.com. Some results may have been estimated or simulated using internal Altera analysis or architecture simulation or modeling and are provided for informational purposes only. Any differences in your system hardware, software, or configuration may affect your actual performance. © Altera Corporation. Altera, the Altera logo, and other Altera marks are trademarks of Altera Corporation in the United States and other countries. Other names and brands may be claimed as the property of others. - 2026-07-08

external_document

Resource Type
Source Name
drupal