Error (11176): Alt_sld_fab.splitter: Port ir_in_0 is not fully defined after elaboration - Error (11176): Alt_sld_fab.splitter: Port ir_in_0 is not fully defined after elaboration
Description Due to a problem in the Quartus® II software version 14.1 and later, you may see this error in designs that include a Quartus II Exported Partition File ( .qxp ) Resolution To work around this problem, create a text file named quartus.ini in your project folder and add the following command: sci_use_legacy_sld_flow=on This problem is scheduled to be fixed in a future release of the Quartus II software.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['FPGA Dev Tools Quartus II Software']
novalue
14.1
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document