Why doesn't the Modular Scatter-Gather DMA core trigger End On Error condition? - Why doesn't the Modular Scatter-Gather DMA core trigger End On Error condition?
Description Due to a problem in the Quartus® II software version 14.1 and later, when Modular Scatter-Gather DMA core is set to “Streaming to Memory-Mapped” mode and error port is enabled, End On Error is not triggered when an error beat enters the write master and the error beat information does not propagate to report port. - The Modular Scatter-Gather DMA core it will incorrectly continue to process the next descriptor(s) Resolution This problem was fixed beginning with the Quartus® II software version 15.1.
Custom Fields values:
['novalue']
Troubleshooting
FB: 474419 321992;
True
['Modular Scatter-Gather DMA IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
15.1
14.1
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document