RapidIO II IP Core Might Send Truncated Data on Avalon-ST Pass-Through Interface if tt = 1 - RapidIO II IP Core Might Send Truncated Data on Avalon-ST Pass-Through Interface if tt = 1 Description When the RapidIO II IP core sends data to the Avalon-ST Pass-Through interface in a transaction with Transport Type value 1, it truncates the payload to a multiple of eight bytes. Resolution This issue has no workaround. To avoid this issue, avoid sending payloads that are not a multiple of eight bytes in packets with ftype 9 and tt 1. This issue will be fixed in a future version of the RapidIO II MegaCore function for IP core variations with a 16-bit device ID. However, refer also to the erratum RapidIO II IP Core Does Not Support Streaming Data Packets With Device ID Width 16 . Custom Fields values: ['novalue'] Troubleshooting novalue True ['novalue'] ['FPGA Dev Tools Quartus II Software'] novalue 12.1 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25