RAM: 1-PORT IP Parameter Editor Is Missing a Legality Check for Invalid Options - RAM: 1-PORT IP Parameter Editor Is Missing a Legality Check for Invalid Options
Description The IP Parameter Editor generates an invalid wrapper for the RAM: 1-PORT IP core when you set the memory block type to Auto and the read-during-write mode to New Data . The invalid wrapper allows you to set the read_during_write_mode_port_a parameter to NEW_DATA_WITH_NBE_READ even if it is an invalid option. This issue affects the Quartus® Prime Standard Edition software and the Quartus Prime Pro Edition software. Resolution Set the read_during_write_mode_port_a parameter to NEW_DATA_NO_NBE_READ inside the generated wrapper.