Error (209048): Verify (Block &ltstart address&gt-&ltend address&gt) failure on device number &ltdevice number&gt - Error (209048): Verify (Block &ltstart address&gt-&ltend address&gt) failure on device number &ltdevice number&gt Description Due to a problem in the Quartus® II software version 14.0 Update 1 and earlier, the Quartus II programmer may fail to program a flash memory device and display this error message during Verify operation. This occurs when using the Parallel Flash loader (PFL) and the USB Blaster II. Resolution This problem has been fixed beginning with the Quartus II software version 14.0 Update 2. Custom Fields values: ['novalue'] Troubleshooting novalue False ['Verification'] ['FPGA Dev Tools Quartus II Software'] 14.0.2 13.1 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25