Configuration Via Protocol (CvP) Not Working for Stratix V Hard IP for PCI Express x2 Variants - Configuration Via Protocol (CvP) Not Working for Stratix V Hard IP for PCI Express x2 Variants
Description Stratix V GX Hard IP for PCI Express variants using CvP and x2 configuration fail during link training initialization. Resolution The workaround is to specify a x4 configuration and let the link downtrain to x2. CvP updates work reliably using this workaround starting with release 12.0 of the Quartus II software. This issue will be fixed in a future version of the Quartus II software.
Custom Fields values:
['novalue']
Troubleshooting
novalue
True
['novalue']
['FPGA Dev Tools Quartus II Software']
novalue
10.1
['Stratix® V FPGAs']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document