Why is Quartus® Prime Pro Edition Software 24.1 not generating IP original scripts for simulation despite being configured to use the 'Traditional Flow'? - Why is Quartus® Prime Pro Edition Software 24.1 not generating IP original scripts for simulation despite being configured to use the 'Traditional Flow'?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 24.1 and earlier, you may generate the new scripts for simulation instead of the traditional scripts despite selecting 'Traditional flow'. Resolution To work around this problem, run the following command instead of generating the scripts from the GUI: ip-setup-simulation --quartus-project=my_proj.qpf --modelsim-flow=traditional This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.
Custom Fields values:
['novalue']
Troubleshooting
22020194300
False
['novalue']
['novalue']
novalue
novalue
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2024-09-23
external_document