Error(19192): File <filename>.sof is incomplete - Power management settings are not set up appropriately on VID part - Error(19192): File <filename>.sof is incomplete - Power management settings are not set up appropriately on VID part Description This error might be seen in the Quartus® Prime Pro Edition Software when programming the .sof file to Stratix® 10 FPGA - Transceiver TX SI Development Kit - DK-SI-1STX-E-A. Resolution To work around this error, you need to put the following complete SmartVID settings into the Quartus® Prime Software project QSF file: set_global_assignment -name VID_OPERATION_MODE "PMBUS MASTER" set_global_assignment -name PWRMGT_BUS_SPEED_MODE "100 KHZ" set_global_assignment -name PWRMGT_SLAVE_DEVICE_TYPE LTM4677 set_global_assignment -name PWRMGT_SLAVE_DEVICE0_ADDRESS 47 set_global_assignment -name PWRMGT_SLAVE_DEVICE1_ADDRESS 48 set_global_assignment -name PWRMGT_SLAVE_DEVICE2_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE3_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE4_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE5_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE6_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE7_ADDRESS 00 set_global_assignment -name PWRMGT_TRANSLATED_VOLTAGE_VALUE_UNIT VOLTS set_global_assignment -name PWRMGT_PAGE_COMMAND_ENABLE ON set_global_assignment -name USE_PWRMGT_SCL SDM_IO14 set_global_assignment -name USE_PWRMGT_SDA SDM_IO11 set_global_assignment -name USE_CONF_DONE SDM_IO16 set_global_assignment -name USE_INIT_DONE SDM_IO0 set_global_assignment -name USE_SEU_ERROR SDM_IO13 Custom Fields values: ['novalue'] Troubleshooting 1606067005 False ['25G Ethernet IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 24.4 22.4 ['Stratix® 10 TX FPGA'] ['novalue'] ['novalue'] ['Stratix® 10 TX FPGA Signal Integrity Dev Kit'] - 2023-06-22

external_document