Why am I seeing “Max Wait Timeout” error or Link Training Failure when running simulations for F-Tile Auto-negotiation and Link Training with Ethernet IP? - Why am I seeing “Max Wait Timeout” error or Link Training Failure when running simulations for F-Tile Auto-negotiation and Link Training with Ethernet IP?
Description For the F-Tile Auto-negotiation and Link Training with the Ethernet IP, if Auto-Negotiation (AN) is disabled, but Link Training (LT) is enabled, the "Max Wait Timeout ” indication is not reliable and you may see an error. If Auto-Negotiation (AN) and Link Training (LT) both are enabled, the "Max Wait Timeout" is reliable and can be used. Resolution Currently there is no workaround for this as disabling Auto-Negotiation (AN) and enabling Link training (LT) is not a valid use case as per IEEE 802.3 specification. This case is only used for debugging purposes, in such a case, max wait timeout should not be used.
Custom Fields values:
['novalue']
Troubleshooting
16024637524
False
['F-Tile Auto-Negotiation and Link Training for Ethernet IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
No plan to fix
24.3
['Agilex™ 7 FPGAs and SoCs', 'Agilex™ 9 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2024-10-06
external_document