Why is the Intel® Stratix® 10 MX and Intel® Stratix® 10 TX device internal Temperature Sensing Diode (TSD) readout always stuck at 25 degrees Celsius? - Why is the Intel® Stratix® 10 MX and Intel® Stratix® 10 TX device internal Temperature Sensing Diode (TSD) readout always stuck at 25 degrees Celsius?
Description Due to a problem in Intel® Quartus® Prime Pro Edition Software version 18.1 and later, the internal TSD readout from Intel® Stratix® 10 MX and TX devices is always stuck at 25 degrees Celsius. This only impacts the following production device variants: Intel® Stratix® 10 MX 1650 Intel® Stratix® 10 MX 2100 Intel® Stratix® 10 TX 1650 Intel® Stratix® 10 TX 2100 Resolution This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 18.1.1.
Custom Fields values:
['novalue']
Troubleshooting
1507120119
False
['Temperature Sensor Stratix® 10 FPGA IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
18.1.1
18.1
['Stratix® 10 MX FPGA', 'Stratix® 10 TX FPGA']
['novalue']
['novalue']
['novalue'] - 2023-01-18
external_document