Why does functional failure occur after performing external scrubbing in Agilex™ 5 devices? - Why does functional failure occur after performing external scrubbing in Agilex™ 5 devices?
Description Due to a problem in Quartus® Prime Pro Edition Software version 24.1 and earlier, you may observed functional failure after performing external scrubbing in Agilex™ 5 devices. Resolution To work around this problem, you can perform full chip reconfiguration to recover non-correctable SEU error. This is schedule to be fixed in a future release of Quartus® Prime Pro Edition Software.
Custom Fields values:
['novalue']
Troubleshooting
15016142607
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
24.1
['Agilex™ 5 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2024-06-03
external_document