Why does transceiver dynamic reconfiguration fail when the "Enable continuous write of all the words needed for reconfiguration" option is enabled in the altgx_reconfig MegaWizard on Stratix IV GX/T and Arria II GX/GZ devices? - Why does transceiver dynamic reconfiguration fail when the "Enable continuous write of all the words needed for reconfiguration" option is enabled in the altgx_reconfig MegaWizard on Stratix IV GX/T and Arria II GX/GZ devices? Description Transceiver dynamic reconfiguration may fail when the "Enable continuous write of all the words needed for reconfiguration" option is enabled in the altgx_reconfig MegaWizard™ on Stratix® IV GX/GT and Arria® II GX/GZ devices due to a problem with the altgx_reconfig MegaWizard. Asserting the write_all signal for one reconfig_clk clock cycle may cause the dynamic reconfiguration process to fail with Quartus® II Software Versions 10.0-SP1 and earlier. To work around this issue, assert the write_all signal for four reconfig_clk cycles, or upgrade to Quartus II Software Version 10.1 or later. Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['novalue'] novalue novalue ['Arria® II GX FPGA', 'Arria® II GZ FPGA', 'Stratix® IV GT FPGA', 'Stratix® IV GX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25