Error: ” .sopcinfo file is missing.” While importing a project from a previous work space in NIOS® II SBT "Eclipse®" - Error: ” .sopcinfo file is missing.” While importing a project from a previous work space in NIOS® II SBT "Eclipse®"
Description This error appears due to a missing reference to the imported .sopcinfo from previous project into the new workspace. Resolution This problem is fixed starting with the Intel® Quartus® Prime Pro Edition software version 20.4. To fix this, follow the next steps: 1. Import the eclipse project o Import-> Nios® II Software Build Tools Project ---> Import Nios® II Software Build Tools Project o Start NIOS® II and select work-space to 'software' folder o Import project code. Select folder for this, and make sure name of project matches folder. o Import BSP files. Select folder for this and again make sure name matches folder. 2. Edit the make file (variable name SOPC_FILE=) and settings.bsp file (Tag name SopcDesignFile=) such that we are pointing to the correct directory of .sopcinfo file.
Custom Fields values:
['novalue']
Troubleshooting
1607102662
False
['Nios® II Processor']
['FPGA Dev Tools Quartus® Prime Software Pro']
20.4
18.1
['Programmable Logic Devices']
['Nios® II Embedded Design Suite (EDS)']
['novalue']
['novalue'] - 2021-08-25
external_document