Compilation fails if the MegaWizard Plug-In Manager creates transmitter PLLs that use SDI or CPRI with phase frequency detector (PFD) feedback turned off for Cyclone IV GX - Compilation fails if the MegaWizard Plug-In Manager creates transmitter PLLs that use SDI or CPRI with phase frequency detector (PFD) feedback turned off for Cyclone IV GX Description If you use the MegaWizard Plug-In Manager to create, at locations PLL_6 and PLL_7, transmitter PLLs that use SDI or CPRI with phase frequency detector (PFD) feedback turned off, compilation of the design fails with an error similar to the following: Error: Can’t place the MPLL or GPLL PLL <tx pll name> in the PLL location PLL_7 because the location operates on compensation mode but the PLL supports only “no compensation” mode . Resolution Manually set PLL operation mode to no_compensation . Custom Fields values: ['novalue'] Troubleshooting novalue True ['Interfaces Communications CPRI (Primary)', 'PLL'] ['FPGA Dev Tools Quartus II Software'] novalue 10.0 ['Cyclone® IV FPGAs'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25

external_document